Programmer Guide/SPU Reference/AVR: Difference between revisions
From STX Wiki
Jump to navigationJump to search
No edit summary |
No edit summary |
||
Line 69: | Line 69: | ||
</math> | </math> | ||
Since {{STx}} version 4.5.0 following two new average modes are available, which were used to implement the spectral averaging mode <code>power</code> of the applications <code>Viewer2</code> (sectioner) and <code>Viewer3</code>. | Since {{STx}} version 4.5.0 the following two new average modes are available, which were used to implement the spectral averaging mode <code>power</code> of the applications <code>Viewer2</code> (sectioner) and <code>Viewer3</code>. | ||
:;power: | :;power: |
Revision as of 10:57, 16 October 2018
Average input X over evaluation cycles.
[SPU AVR X TYP T RS OUT Y]
input | description | data type | value type | default value |
---|---|---|---|---|
X | data to be averaged | number, vector, matrix | variable | |
TYP | averaging method | number (int.), string | constant | |
T | averaging parameter, depends on method | number or n.c. | TYP=1→variable TYP≠2→constant | |
RS | reset flag | number or n.c. | variable | |
output | description | data type | value type | comment |
Y | averaged input data | same type as X | variable |
- Description
The averaging algorithm is defined by the inputs TYP and T. The atom averages the elements X[i,j]t over evaluation cycles t (i=row index, j=column index, t=cycle counter) and stores the averaged value in the element Y[i,j]t.
The cycle counter t is initialized with 0 and incremented by 1 after each evaluation cycle. The cycle counter is reset, if the input RS is set to a value greater than 0
. The input RS is checked each time the SPU is started.
- infinite average
- TYP=
0
orlinear
- T=
0
- running average
- TYP=
0
orlinear
- T>
0
; T is the (integer) number of averaging cycles - exponential average
- TYP=
1
orexponential
0
<T<1
; T is the averaging factor- minimum
- TYP=
2
orminimum
- T is not used
- maximum
- TYP=
3
ormaximum
- T is not used
Since STx version 4.5.0 the following two new average modes are available, which were used to implement the spectral averaging mode power
of the applications Viewer2
(sectioner) and Viewer3
.
- power
- TYP=
4
orpower
- T is not used
- each input element Xi,j is squared
- same averaging as for TYP=
0
is performed - square root of each output element Yi,j is taken
- db-power
- TYP=
5
ordbpower
- T is not used
- each input element Xi,j is converted from dB to squared magnitude (power)
- same averaging as for TYP=
0
is performed - each output element Yi,j is converted to dB
- See also
<SP-atoms>