Average input X over evaluation cycles.
[SPU AVR X TYP T RS OUT Y]
dir. | name | description | type | default |
---|---|---|---|---|
in | X | a number, vector or matrix containing the data to be averaged | variable | |
in | TYP | a number or string; defines the averaging method | constant | |
in | T | averaging parameter (number); depends on method | variable, only for TYP=2 | |
in | RS | reset flag (number) | variable, only checked on SPU start | |
out | Y | averaged input X; same type as X |
- Description
The averaging algorithm is defined by the inputs TYP and T. The atom averages the elements X[i,j]t over evaluation cycles t (i=row index, j=column index, t=cycle counter) and stores the averaged value in the element Y[i,j]t.
The cycle counter t is initialized with 0 and incremented by 1 after each evaluation cycle. The cycle counter is reset, if the input RS is set to a value greater than 0
. The input RS is checked each time the SPU is started.
- infinite average
- TYP=
0
orlinear
- T=
0
- running average
- TYP=
0
orlinear
- T>
0
; T is the (integer) number of averaging cycles - exponential average
- TYP=
1
orexponential
0
<T<1
; T is the averaging factor- minimum
- TYP=
2
orminimum
- T is not used
- maximum
- TYP=
3
ormaximum
- T is not used
- See also